Sec-1302, Sec-1303, Sec-1304 – Dell POWEREDGE M1000E User Manual

Page 625: Sec-1305

Advertising
background image

Fabric OS Message Reference

549

53-1001767-01

SEC-1302

90

SEC-1302

Message

<timestamp>, [SEC-1302], <sequence-number>,, INFO, <system-name>, This switch

does not have all the required PKI objects correctly installed.

Probable Cause

Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

INFO

SEC-1303

Message

<timestamp>, [SEC-1303], <sequence-number>,, INFO, <system-name>, This software

version does not support security.

Probable Cause

Indicates the currently installed software version does not support the Brocade Secure Fabric OS
feature.

Recommended

Action

Run the firmwareDownload command to update the firmware to the latest version for your specific
switch. Verify the firmware you are installing supports the Brocade Secure Fabric OS feature.

Severity

INFO

SEC-1304

Message

<timestamp>, [SEC-1304], <sequence-number>,, INFO, <system-name>, This switch has

no security license.

Probable Cause

Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify the fabric is still consistent. All the switches should be
in the ready state. If a switch is in the error state, the database might not be correctly updated for
that specific switch.

Severity

INFO

SEC-1305

Message

<timestamp>, [SEC-1305], <sequence-number>,, INFO, <system-name>, This switch has

no zoning license.

Advertising