Zolb system messages, Chapter 110 zolb system messages, Zolb-1001 – Dell POWEREDGE M1000E User Manual

Page 731

Advertising
background image

Fabric OS Message Reference

655

53-1001767-01

Chapter

110

ZOLB System Messages

ZOLB-1001

Message

<timestamp>, [ZOLB-1001], <sequence-number>,, ERROR, <system-name>, ZONELIB

<error message>

Probable Cause

Indicates there was an internal timeout on the inter process communication (IPC) between the
name server (NS) and the zoning modules. This usually indicates that the system was busy.

Recommended

Action

This message generates core dump files of the related modules (zoned, nsd, rcsd).

If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command to save these core files and contact your switch service provider.

Severity

ERROR