Em-1051, Em-1057, Em-1058 – Dell POWEREDGE M1000E User Manual

Page 238: Em-1059

Advertising
background image

162

Fabric OS Message Reference

53-1001767-01

EM-1051

22

EM-1051

Message

<timestamp>, [EM-1051], <sequence-number>,, INFO, <system-name>,

<FRU Id>

:

Inconsistency detected, FRU re-initialized.

Probable Cause

Indicates that an inconsistent state was found in the field-replaceable unit (FRU). This occurs if the
state of the FRU was changing during a failover. The FRU is reinitialized and traffic might have been
disrupted.

Recommended

Action

No action is required.

Severity

INFO

EM-1057

Message

<timestamp>, [EM-1057], <sequence-number>,, WARNING, <system-name>, Blade:<Slot

Id> is getting reset:<Fault reason>.

Probable Cause

Indicates the blade is being automatically reset because of known resetable transient errors such
as an application-specific integrated circuit (ASIC) parity error.

Recommended

Action

No action is required if the switch does not reach the reset threshold for the switch or blade. If the
reset threshold is reached on the switch or blade, the switch or blade will be faulted and should be
replaced.

Severity

WARNING

EM-1058

Message

<timestamp>, [EM-1058], <sequence-number>,, WARNING, <system-name>, Switch gets

reset:

<Fault reason>

Probable Cause

Indicates the switch is being automatically reset because of a known resetable transient problem
such as an application-specific integrated circuit (ASIC) parity error.

Recommended

Action

No action is required if the switch does not reach the reset threshold for the switch or blade. If the
reset threshold is reached on the switch or blade, the switch or blade will be faulted and should be
replaced.

Severity

WARNING

EM-1059

Message

<timestamp>, [EM-1059], <sequence-number>, FFDC, ERROR, <system-name>, <Slot

number or Switch> with id <FRU Id> cannot be found in the fru description xml

file.

Probable Cause

Indicates that a blade inserted in the specified slot or the switch (for nonbladed switches) is not
compatible with the switch configuration software. The system may not be usable.

Advertising