Sulb-1039, Sulb-1040 – Dell POWEREDGE M1000E User Manual

Page 697

Advertising
background image

Fabric OS Message Reference

621

53-1001767-01

SULB-1039

97

SULB-1039

Message

<timestamp>, [SULB-1039], INFO, FIRMWARE, CP has completed relocating the internal

firmware image.

Probable Cause

Indicates that the firmwareDownload command process has been completed normally on the CP.

Recommended

Action

Run the firmwareShow command to verify the firmware versions.

Severity

INFO

SULB-1040

Message

<timestamp>, [SULB-1040], INFO, WARNING, An error has occurred during relocation

of the internal image on the CP.

Probable Cause

Indicates an error has occurred during the relocation of the internal image. The error may be
caused by inconsistent internal firmware image. It may also be caused by the internal Ethernet
failure.

Recommended

Action

Run the firmwareShow command to verify the firmware versions. Run the firmwareDownload
command again if the firmware is not updated.

This will cause the internal image to be relocated again. If the problem persists, contact your switch
service provider.

Severity

WARNING

Advertising