Trce-1011, Trce-1012 – Dell POWEREDGE M1000E User Manual

Page 714

Advertising
background image

638

Fabric OS Message Reference

53-1001767-01

TRCE-1011

102

Probable Cause

Indicates that the trace daemon (traced), used for transferring trace files, failed to start. The trace
capability within the switch is unaffected. The traced facility is normally restarted automatically by
the system after a brief delay.

Recommended

Action

If the message persists, restart the CP (dual-CP system) or restart the switch.

Run the supportFtp command to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.

Severity

ERROR

TRCE-1011

Message

<timestamp>, [TRCE-1011], <sequence-number>,, INFO, <system-name>, Trace dump

manually transferred to target ' <optional string to indicate which slot the dump

is ftped out.> ': <result>.

Probable Cause

Indicates that a manual transfer of trace dump files has occurred.

Recommended

Action

No action is required.

Severity

INFO

TRCE-1012

Message

<timestamp>, [TRCE-1012], <sequence-number>,, WARNING, <system-name>, The system

was unable to retrieve trace information from slot

<Slot number of the blade

the attempt was made on>

.

Probable Cause

Indicates that communication between the main system and the indicated slot is unavailable.

Recommended

Action

Make sure the blade is enabled and retry the command. If the blade is already enabled, run the
supportSave command and contact your switch service provider.

Severity

WARNING

Advertising