266

Fabric OS Message Reference

53-1001767-01

FICU-1004

36

Severity

WARNING

FICU-1004

Message

<timestamp>, [FICU-1004], <sequence-number>,, WARNING, <system-name>, <function

name>: Failed to set fabric manager server (FMS) mode: conflicting PID

Format:<pid_format>, FMS Mode:<mode>.

Probable Cause

Indicates that a process ID (PID) format conflict was encountered. The core PID format is required
for fibre connectivity control unit port (FICON-CUP).

The pid_format variable displays the PID format currently running on the fabric, and is one of the
following:

0 is VC-encoded PID format

1 is core PID format

2 is extended-edge PID format

FMS mode displays whether fibre connectivity (FICON) Management Server mode is enabled; a 0
means this mode is enabled and a 1 means this mode is disabled.

Recommended

Action

For FICON Management Server mode (fmsMode) to be enabled, the core PID format must be used
in the fabric. Change the PID format to core PID using the configure command and re-enable
fmsMode using the ficonCupSet command. Refer to the Fabric OS Administrator’s Guide for
information on core PID mode and the Fabric OS Command Reference Manual for information on
these commands.

Severity

WARNING

FICU-1005

Message

<timestamp>, [FICU-1005], <sequence-number>,, ERROR, <system-name>, Failed to

initialize <module>, rc = <error>.

Probable Cause

Indicates that the initialization of a module within the fibre connectivity control unit port
(FICON-CUP) daemon failed.

Recommended

Action

Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference Manual
for more information on this command.

Severity

ERROR

FICU-1006

Message

<timestamp>, [FICU-1006], <sequence-number>,, WARNING, <system-name>, Control

Device Allegiance Reset: (Logical Path: 0x<PID>:0x<channel image ID>)

Probable Cause

Indicates that the path with the specified PID and channel image ID lost allegiance to a fibre
connectivity control unit port (FICON-CUP) device.