Fabric OS Message Reference

53-1001767-01

FW-1442

42

Severity

INFO

FW-1442

Message

<timestamp>, [FW-1442], <sequence-number>,, INFO, <system-name>, <FRU label>

state has changed to <FRU state>.

Probable Cause

Indicates that the state of the specified field-replaceable unit (FRU) has changed to “on”.

Recommended

Action

No action is required. Verify that the event was planned.

Severity

INFO

FW-1443

Message

<timestamp>, [FW-1443], <sequence-number>,, INFO, <system-name>, <FRU label>

state has changed to <FRU state>.

Probable Cause

Indicates that the state of the specified field-replaceable unit (FRU) changed to “off”.

Recommended

Action

No action is required. Verify that the event was planned.

Severity

INFO

FW-1444

Message

<timestamp>, [FW-1444], <sequence-number>,, WARNING, <system-name>, <FRU label>

state has changed to <FRU state>.

Probable Cause

Indicates that the state of the specified field-replaceable unit (FRU) has changed to “faulty”.

Recommended

Action

Replace the FRU.

Severity

WARNING

FW-1445

Message

<timestamp>, [FW-1445], <sequence-number>,, INFO, <system-name>, Four power

supplies are now required for 2X redundancy, Switch Status Policy values changed.

Probable Cause

Indicates that the switch now requires 4 power supplies and previous Switch Status Policy
parameters will be overwritten to reflect this. The presence of an AP blade means that more than
one power supply may be required to provide adequate power. So (even if the AP blade is powered
down or removed) the Switch Status policy values will now reflect the need for 4 power supplies to
maintain full (2X) redundancy.