Fabric OS Message Reference

467

53-1001767-01

Chapter

77

PLAT System Messages

PLAT-1000

Message

<timestamp>, [PLAT-1000], <sequence-number>, FFDC, CRITICAL, <system-name>,

<Function name> <Error string>

Probable Cause

Indicates nonrecoverable PCI errors have been detected.

Recommended

Action

The system will be faulted and might automatically reboot.

If the system does not reboot, then try issuing the reboot command from a command-line prompt.

Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.

Severity

CRITICAL

PLAT-1001

Message

<timestamp>, [PLAT-1001], <sequence-number>,, INFO, <system-name>, CP <Identifies

which CP (0 or 1) is doing the reset> resetting other CP (double reset may occur).

Probable Cause

Indicates the other CP is being reset. This message is typically generated by a CP that is in the
process of becoming the active CP. Note that in certain circumstances a CP may experience a
double reset and reboot twice in a row. A CP can recover automatically even if it has rebooted twice.

Recommended

Action

No action is required.

Severity

INFO

PLAT-1002

Message

<timestamp>, [PLAT-1002], <sequence-number>,, CRITICAL, <system-name>, CP

<Identifies which CP (0 or 1) is generating the message>: <Error message> CP Fence

<CP Fence register. Contents (2 bytes) are platform-specific> <CP Error register.

Contents are platform-specific> CP Error <CP Error register. Contents are

platform-specific>.

Probable Cause

Indicates that the CP cannot access the I2C subsystem either because of an error condtion or
being fenced or isolated from the I2C bus.

Recommended

Action

Reboot the CP if it does not reboot itself. Reseat the CP if rebooting does not solve the problem. If
the problem still persists, then replace the CP.