Fw-1402, Fw-1403, Fw-1404 – Dell POWEREDGE M1000E User Manual
Page 415: Fw-1405
Fabric OS Message Reference
339
53-1001767-01
FW-1402
42
FW-1402
Message
<timestamp>, [FW-1402], <sequence-number>,, WARNING, <system-name>, <Label>, is
above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause
Indicates that the flash usage percentage has risen above the high boundary. Flash increases and
decreases slightly with normal operation of the switch. Excessive permanent increases can lead to
future problems.
Recommended
Action
You might have to remove some unwanted files to create some flash space. Run the supportSave
command to remove files from the kernel space.
Severity
WARNING
FW-1403
Message
<timestamp>, [FW-1403], <sequence-number>,, INFO, <system-name>, <Label>, is
between high and low boundaries(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause
It means some process is using more memory or cpu.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO
FW-1404
Message
<timestamp>, [FW-1404], <sequence-number>,, WARNING, <system-name>, <Label>,is
above high boundaries(High=<High value>, Low=<Low value>). Current value is
<Value> <Unit>.
Probable Cause
It means CPU or memory usage is above its threshold. If this RASLOG is pertaining to memory
usage then the usage is above middle memory threshold.
Recommended
Action
No action is required.
Severity
WARNING
FW-1405
Message
<timestamp>, [FW-1405], <sequence-number>,, INFO, <system-name>, <Label>,is above
high boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause
It means memory usage below low threshold.