Fw-1402, Fw-1403, Fw-1404 – Dell POWEREDGE M1000E User Manual

Page 415: Fw-1405

Advertising
background image

Fabric OS Message Reference

339

53-1001767-01

FW-1402

42

FW-1402

Message

<timestamp>, [FW-1402], <sequence-number>,, WARNING, <system-name>, <Label>, is

above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>

<Unit>.

Probable Cause

Indicates that the flash usage percentage has risen above the high boundary. Flash increases and
decreases slightly with normal operation of the switch. Excessive permanent increases can lead to
future problems.

Recommended

Action

You might have to remove some unwanted files to create some flash space. Run the supportSave
command to remove files from the kernel space.

Severity

WARNING

FW-1403

Message

<timestamp>, [FW-1403], <sequence-number>,, INFO, <system-name>, <Label>, is

between high and low boundaries(High=<High value>, Low=<Low value>). Current value

is <Value> <Unit>.

Probable Cause

It means some process is using more memory or cpu.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

FW-1404

Message

<timestamp>, [FW-1404], <sequence-number>,, WARNING, <system-name>, <Label>,is

above high boundaries(High=<High value>, Low=<Low value>). Current value is

<Value> <Unit>.

Probable Cause

It means CPU or memory usage is above its threshold. If this RASLOG is pertaining to memory
usage then the usage is above middle memory threshold.

Recommended

Action

No action is required.

Severity

WARNING

FW-1405

Message

<timestamp>, [FW-1405], <sequence-number>,, INFO, <system-name>, <Label>,is above

high boundary(High=<High value>, Low=<Low value>). Current value is <Value>

<Unit>.

Probable Cause

It means memory usage below low threshold.