Ps-1004, Ps-1005, Ps-1006 – Dell POWEREDGE M1000E User Manual

Page 554

Advertising
background image

478

Fabric OS Message Reference

53-1001767-01

PS-1004

80

Probable Cause

Indicates that the restoring configuration has failed to set the end-to-end monitoring mask on at
least one ISL port.

Recommended

Action

No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is
enabled. ISL monitoring can only be disabled through the Fabric Access API.

Severity

WARNING

PS-1004

Message

<timestamp>, [PS-1004], <sequence-number>,, WARNING, <system-name>, Failed to add

end-to-end monitors on port

<port>

which is an ISL port.

Probable Cause

Indicates that the restoring configuration has attempted to add end-to-end monitors on at least one
ISL port.

Recommended

Action

No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is
enabled. ISL monitoring can only be disabled through the Fabric Access API.

Severity

WARNING

PS-1005

Message

<timestamp>, [PS-1005], <sequence-number>,, WARNING, <system-name>, ISL monitor

on port

<port>

stopped counting because no hardware resources are available

Probable Cause

Indicates that ISL and end-to-end monitors have used up all hardware resources.

Recommended

Action

To resume counting, delete some end-to-end monitors sharing the same hardware resource pool.

Severity

WARNING

PS-1006

Message

<timestamp>, [PS-1006], <sequence-number>,, WARNING, <system-name>, Failed to add

fabricmode toptalker monitors on domain=<domain id>, because end-to-end monitors

are configured on this switch.

Probable Cause

Indicates the end-to-end monitors are configured on the switch.

Recommended

Action

Delete the end-to-end monitors on that switch and re-install the fabricmode TopTalker monitor.
End-to-end monitors and fabricmode Top Talker monitors are mutually exclusive.

Severity

WARNING

Advertising