Pswp system messages, Chapter 81, Pswp-1001 – Dell POWEREDGE M1000E User Manual
Page 557: Pswp-1002, Pswp-1003, Chapter
Fabric OS Message Reference
481
53-1001767-01
Chapter
81
PSWP System Messages
PSWP-1001
Message
<timestamp>, [PSWP-1001], <sequence-number>,, INFO, <system-name>, PID for port
<wwn name corresponding to source port> and port <wwn name corresponding to
destination port> are swapped. New PID for port <wwn name corresponding to source
port> is <wwn name corresponding to destination port> and port <new area
corresponding to source wwn> is <new area corresponding to destination wwn>.
Probable Cause
Indicates that the portSwap command has been issued.
Recommended
Action
No action is required.
Severity
INFO
PSWP-1002
Message
<timestamp>, [PSWP-1002], <sequence-number>,, INFO, <system-name>, Port Swap
feature enabled.
Probable Cause
Indicates that the portSwap feature has been enabled in the switch.
Recommended
Action
No action is required.
Severity
INFO
PSWP-1003
Message
<timestamp>, [PSWP-1003], <sequence-number>,, INFO, <system-name>, Port Swap
feature disabled.
Probable Cause
Indicates that the portSwap command feature has been disabled in the switch.
Recommended
Action
No action is required.
Severity
INFO