Fabric OS Message Reference

53-1001767-01

FCR-1063

34

Probable Cause

Indicates that the maximum number of supported EX_ports or VEX_ports was exceeded. To enable
the specified port, disable any other operational port then re-enable the port.

Recommended

Action

No action is required.

Severity

INFO

FCR-1063

Message

<timestamp>, [FCR-1063], <sequence-number>,, INFO, <system-name>, Fabric <fabric

ID> for switch with domain ID: <domain ID> mismatch with local fabric ID <local

fabric ID>.

Probable Cause

Indicates that the fabric ID of the switch does not match the local switch.

Recommended

Action

Run the switchShow command to display the fabric ID. Change the fabric ID to match on both ends
by modifying either the local or remote host using the fcrConfigure command.

Severity

INFO

FCR-1064

Message

<timestamp>, [FCR-1064], <sequence-number>,, ERROR, <system-name>, Fabric ID of

backbone FC-Routers mismatch or overlap.

Probable Cause

Indicates that either (1) a backbone fabric split and both are connected to common edge fabrics, or
(2) the fabric IDs of two backbone fabrics connected to an edge fabric are the same.

Recommended

Action

If the backbone fabric split, merge the fabrics.

If two (or more) backbone fabrics have the same IDs, make the fabric IDs unique using fcrConfigure
command.

Severity

ERROR

FCR-1065

Message

<timestamp>, [FCR-1065], <sequence-number>,, ERROR, <system-name>, Fabric on port

<port number>

was assigned two different fabric IDs.

Probable Cause

Indicates that another port on the switch is connected to the same edge fabric with a different
fabric ID assignment.

Recommended

Action

Change the port fabric ID to same value as the other ports connected to the edge fabric using the
portCfgExport or portCfgVexport commands.

Severity

ERROR