Fabric OS Message Reference

53-1001767-01

SEC-1089

90

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

ERROR

SEC-1089

Message

<timestamp>, [SEC-1089], <sequence-number>,, ERROR, <system-name>, Policy name

<policy name> was not found.

Probable Cause

Indicates the security policy name in the secPolicyAdd command does not exist.

Recommended

Action

Create the appropriate security policy first, then use its name in the secPolicyAdd command to add
new members.

Severity

ERROR

SEC-1090

Message

<timestamp>, [SEC-1090], <sequence-number>,, ERROR, <system-name>, SCC list

contains FCS member. Please remove member from the FCS policy first.

Probable Cause

Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

ERROR

SEC-1091

Message

<timestamp>, [SEC-1091], <sequence-number>,, ERROR, <system-name>, No policy to

remove.

Probable Cause

Indicates the specified policy member does not exist or the policy itself does not exist.

Recommended

Action

Verify that the security policy name or member ID is correct.

Severity

ERROR