CDR-1001

Message

<timestamp>, [CDR-1001], <sequence-number>,, ERROR, <system-name>, Port

<port

number>

port fault. Please change the SFP or check cable

Probable Cause

Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, a faulty cable
between peer ports, or that the port speed configuration does not match the capability of the SFP.

Recommended

Action

Ensure that you are using compatible SFPs on the peer ports.

Verify whether the SFPs have deteriorated or the Fibre Channel cable is faulty. Replace the SFPs or
cable, if necessary.

Severity

ERROR

CDR-1002

Message

<timestamp>, [CDR-1002], <sequence-number>, FFDC, ERROR, <system-name>, Port

<port number>

chip faulted due to internal error.

Probable Cause

Indicates an internal error.

Recommended

Action

For a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade to recover
the system. For a non-bladed system, perform fastBoot command on the switch to recover the
system.

Severity

ERROR

CDR-1003

Message

<timestamp>, [CDR-1003], <sequence-number>, FFDC, CRITICAL, <system-name>, <slot

number>, <chip index> HW ASIC chip error type =0<chip error type>

Probable Cause

Indicates an internal error in the application specific integrated circuit (ASIC) hardware that may
degrade data traffic.

Recommended

Action

Whenever this error occurs, restart the system at the next maintenance window. If the problem
persists, replace the blade.