Em-1009, Em-1010, Em-1011 – Dell POWEREDGE M1000E User Manual

Page 228: Em-1012

Advertising
background image

152

Fabric OS Message Reference

53-1001767-01

EM-1009

22

EM-1009

Message

<timestamp>, [EM-1009], <sequence-number>, FFDC, CRITICAL, <system-name>,

<FRU

Id>

powered down unexpectedly.

Probable Cause

Indicates that the environmental monitor (EM) received an unexpected power-down notification
from the specified field-replaceable unit (FRU). This might indicate a hardware malfunction in the
FRU.

Recommended

Action

Try reseating the FRU. If the message persists, replace the FRU. Refer to the Brocade 48000
Hardware Reference Manual
for more information about chassisConfig modes and supported
blades.

Severity

CRITICAL

EM-1010

Message

<timestamp>, [EM-1010], <sequence-number>, FFDC, CRITICAL, <system-name>,

Received unexpected power down for <FRU Id> But <FRU Id> still has power.

Probable Cause

Indicates that the environmental monitor (EM) received an unexpected power-down notification
from the specified field-replaceable unit (FRU). However, the specified FRU still appears to be
powered up after four seconds.

Recommended

Action

Try reseating the blade. If this fails to correct the error, replace the blade.

Severity

CRITICAL

EM-1011

Message

<timestamp>, [EM-1011], <sequence-number>, FFDC, CRITICAL, <system-name>,

Received unexpected power down for

<FRU Id>

, but cannot determine if it has

power.

Probable Cause

Indicates that the environmental monitor (EM) received an unexpected power-down notification
from the field-replaceable unit (FRU) specified; however, after four seconds it cannot be
determined if it has powered down or not.

Recommended

Action

Try reseating the blade. If this fails to correct the error, replace the blade.

Severity

CRITICAL

EM-1012

Message

<timestamp>, [EM-1012], <sequence-number>, FFDC, CRITICAL, <system-name>, <FRU

Id> failed <state> state transition, unit faulted.