Fabric OS Message Reference

53-1001767-01

EM-1016

22

Severity

WARNING

EM-1016

Message

<timestamp>, [EM-1016], <sequence-number>,, WARNING, <system-name>, Cold recovery

failed (

<Return code>

).

Probable Cause

Indicates that a problem was discovered when performing consistency checks during a cold boot.

Recommended

Action

Monitor the switch.

If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.

Severity

WARNING

EM-1017

Message

<timestamp>, [EM-1017], <sequence-number>,, WARNING, <system-name>, Uncommitted

WWN change detected. Cold reboot required.

Probable Cause

Indicates that a user did not commit a changed world wide name (WWN) value prior to executing a
reboot, power cycle, or firmwareDownload operation.

Recommended

Action

Change and commit the new WWN value.

Severity

WARNING

EM-1018

Message

<timestamp>, [EM-1018], <sequence-number>, FFDC, CRITICAL, <system-name>, CP

blade in slot <slot number> failed to retrieve current chassis type (<detailed

fault descriptor>/<PLACE HOLDER>/0x<PLACE HOLDER>).

Probable Cause

Indicates that there was a failure to read the chassis type from the system.

Recommended

Action

Verify that the control processor (CP) blade is operational and is properly seated in its slot.

Severity

CRITICAL

EM-1019

Message

<timestamp>, [EM-1019], <sequence-number>,, WARNING, <system-name>, Current

chassis configuration option (

<Chassis config option currently in effect>

)

is not compatible with standby firmware version (Pre 4.4), cannot allow HA Sync.