Fabs-1008, Fabs-1009, Fabs-1010 – Dell POWEREDGE M1000E User Manual

Page 267: Fabs-1011

Advertising
background image

Fabric OS Message Reference

191

53-1001767-01

FABS-1008

27

Severity

WARNING

FABS-1008

Message

<timestamp>, [FABS-1008], <sequence-number>,, WARNING, <system-name>,

<Function

name>

: Media oid mapping failed

Probable Cause

Indicates that the Fabric OS was unable to locate a necessary object handle. This is usually an
internal Fabric OS problem or file corruption.

Recommended

Action

Reboot or power cycle the switch.

Severity

WARNING

FABS-1009

Message

<timestamp>, [FABS-1009], <sequence-number>,, WARNING, <system-name>,

<Function

name>

: type is not media

Probable Cause

Indicates that the Fabric OS was unable to locate an appropriate object handle. This is usually an
internal Fabric OS problem or file corruption.

Recommended

Action

Reboot or power cycle the switch.

Severity

WARNING

FABS-1010

Message

<timestamp>, [FABS-1010], <sequence-number>,, WARNING, <system-name>, <Function

name>: Wrong media_event <Event number>

Probable Cause

Indicates that the Fabric OS detected an unknown event type. This is usually an internal Fabric OS
problem or file corruption.

Recommended

Action

Reboot or power cycle the switch.

If the message persists, run the firmwareDownload command to update the firmware.

Severity

WARNING

FABS-1011

Message

<timestamp>, [FABS-1011], <sequence-number>,, ERROR, <system-name>, <Method

name>[<Method tag number>]:Invalid input state 0x<Input state code>

Probable Cause

Indicates an unrecognized state code was used in an internal Fabric OS message for a FRU.

Advertising