98

Fabric OS Message Reference

53-1001767-01

CNM-1005

16

Probable Cause

Indicates that the Crypto service is enabled or disabled on the switch.

Recommended

Action

No action is required.

Severity

INFO

CNM-1005

Message

<timestamp>, [CNM-1005], <sequence-number>,, INFO, <system-name>, Posting event

CNM_EVT_GRP_LEADER_ELECTED Name [<nodeName>], WWN [<WWn>].

Probable Cause

Indicates that the cluster encryption group (EG) leader is elected.

Recommended

Action

No action is required.

Severity

INFO

CNM-1006

Message

<timestamp>, [CNM-1006], <sequence-number>,, INFO, <system-name>, Posting event

CNM_EVT_NODE_JOIN nodeName [<nodeName>], wwn [<wwn>], ipaddress [<ipAddr>].

Probable Cause

Indicates that the member node has joined.

Recommended

Action

No action is required.

Severity

INFO

CNM-1007

Message

<timestamp>, [CNM-1007], <sequence-number>,, INFO, <system-name>, Posting event

CNM_EVT_GRP_LEADER_FAILED Name [<nodeName>].

Probable Cause

Indicates that the Group Leader has failed.

Recommended

Action

No action is required.

Severity

INFO

CNM-1008

Message

<timestamp>, [CNM-1008], <sequence-number>,, INFO, <system-name>, Posting event

CNM_EVT_NODE_EJECT nodeName [<nodeName>], wwn [<wwn>].

Probable Cause

Indicates that the node is ejected from the encryption group (EG).