Fabric OS Message Reference

53-1001767-01

FW-1204

42

FW-1204

Message

<timestamp>, [FW-1204], <sequence-number>,, INFO, <system-name>, <Port Name>,

<Label>, value has changed(High=<High value>, Low=<Low value>). Current value is

<Value> <Unit>.

Probable Cause

Indicates that the trunk utilization has changed.

Recommended

Action

No action required.

Severity

INFO

FW-1205

Message

<timestamp>, [FW-1205], <sequence-number>,, INFO, <system-name>, <Port Name>,

<Label>, is below low boundaries (High=<High value>, Low=<Low value>). Current

value is <Value> <Unit>.

Probable Cause

Indicates that the trunk utilization has reduced.

Recommended

Action

No action required.

Severity

INFO

FW-1206

Message

<timestamp>, [FW-1206], <sequence-number>,, WARNING, <system-name>, <Port Name>,

<Label>, is between high and low boundaries (High=<High value>, Low=<Low value>).

Current value is <Value> <Unit>.

Probable Cause

Indicates that the trunk utilization has gone above its threshold level.

Recommended

Action

Increase the bandwidth by adding more links to the trunk.

Severity

WARNING

FW-1207

Message

<timestamp>, [FW-1207], <sequence-number>,, INFO, <system-name>, <Port Name>,

<Label>, is between high and low boundaries (High=<High value>, Low=<Low value>).

Current value is <Value> <Unit>.

Probable Cause

Indicates that the trunk utilization is between low and high thresholds.

Recommended

Action

No action required.