Ficu system messages, Chapter 36, Ficu-1001 – Dell POWEREDGE M1000E User Manual

Page 341: Ficu-1002, Ficu-1003, Chapter

Advertising
background image

Fabric OS Message Reference

265

53-1001767-01

Chapter

36

FICU System Messages

FICU-1001

Message

<timestamp>, [FICU-1001], <sequence-number>,, ERROR, <system-name>, <function

name>: config<config Set(key)|Get(key)| Save> failed rc = <error>.

Probable Cause

Indicates that one of the configuration management functions failed. The key variable is a part of
the Fabric OS configuration database and is for support use only. The error variable is an internal
error number.

Recommended

Action

Execute an haFailover command on the switch if it has redundant control processors (CPs) or
restart the switch. Run the supportSave command to check if your flash is full. If the flash is full,
run the supportSave command to clear the core files. Refer to the Fabric OS Command Reference
Manual for more information on these commands.

Severity

ERROR

FICU-1002

Message

<timestamp>, [FICU-1002], <sequence-number>,, ERROR, <system-name>, <function

name>: Failed to get RNID from Management Server: Domain=<domain>, rc=<error>.

Probable Cause

Indicates that the fibre connectivity control unit port (FICON-CUP) daemon failed to get the switch
request node ID (RNID) from the management server because of a Fabric OS problem. The domain
variable displays the domain ID of the target switch for this RNID. The error variable is an internal
error number.

Recommended

Action

If this is a bladed switch, execute the haFailover command. If the problem persists, or if this is a
nonbladed switch, download a new firmware version using the firmwareDownload command. Refer
to the Fabric OS Command Reference Manual for more information on these commands.

Severity

ERROR

FICU-1003

Message

<timestamp>, [FICU-1003], <sequence-number>,, WARNING, <system-name>, <function

name>: <message> FICON-CUP License Not Installed: (<error>).

Probable Cause

Indicates that the fibre connectivity control unit port (FICON-CUP) license is not installed on the
switch.

Recommended

Action

Run the licenseShow command to check the installed licenses on the switch. The switch cannot be
managed using FICON-CUP commands until the FICON-CUP license is installed. Contact your switch
supplier for a FICON-CUP license. Run the licenseAdd command to add the license to your switch.