Fabric OS Message Reference

53-1001767-01

SPC-3005

93

Probable Cause

Indicates the output wrapping KEK for the DEK to be created does not exist within the EE Crypto
Module.

Recommended

Action

For opaque key vaults such as RKM, recover the missing Master Key to current or alternate
position.

Severity

ERROR

SPC-3005

Message

<timestamp>, [SPC-3005], <sequence-number>,, ERROR, <system-name>, <slot number

containing Encryption Engine>, <module name>:DEK inject error: <SP status code>,

DEK: <DEK octet 1 or other info> <DEK octet 2> <DEK octet 3> <DEK octet 4>.

Probable Cause

Indicates the cause depends on the SP status code:

•

14 - Attempt to inject a DEK to an invalid FPGA table index

•

14 - Invalid input DEK format

•

32 - DEK could not be unwrapped

•

33 - FGPA error upon inject

•

73 - Invalid KEK format

Recommended

Action

Contact technical support.

Severity

ERROR

SPC-3006

Message

<timestamp>, [SPC-3006], <sequence-number>,, ERROR, <system-name>, <slot number

containing Encryption Engine>, <module name>:DEK rewrap error: <SP status code>,

DEK: <DEK octet 1 or other info> <DEK octet 2> <DEK octet 3> <DEK octet 4>.

Probable Cause

Indicates the cause depends on the SP status code:

•

2 - Invalid input DEK format

•

14 - Rewrapping not allowed: primary KEK generation is in progress

•

31 - DEK could not be wrapped

•

32 - DEK could not be unwrapped

•

33 - FGPA error upon inject

•

73 - Invalid KEK format

Recommended

Action

For status code 14, complete primary KEK generation; otherwise, contact technical support.