Fabric OS Message Reference

163

53-1001767-01

EM-1060

22

Recommended

Action

Replace the blade. Make sure the replacement is compatible with your switch type.

Severity

ERROR

EM-1060

Message

<timestamp>, [EM-1060], <sequence-number>,, WARNING, <system-name>, Stopping

synchronization of the system due to blade incompatibility with software version

on standby CP.

Probable Cause

Indicates a blade in the system is not supported by the release on the standby control processor
(CP).

Recommended

Action

Remove all blades of this type or upgrade your standby CP. Once an appropriate action is taken,
this CP must be rebooted or the haSyncStart command must be run successfully. Until this is done,
the system will remain out of synchronization.

Severity

WARNING

EM-1061

Message

<timestamp>, [EM-1061], <sequence-number>,, WARNING, <system-name>,

Synchronization halted. Remove all blades of type

<Blade Type Id>

or upgrade

your standby CP, then reboot or run haSyncStart.

Probable Cause

Indicates a blade in the system is not supported by the release on the standby control processor
(CP).

Recommended

Action

Remove all blades of this type or upgrade your standby CP. Once an appropriate action is taken,
this CP must be rebooted or the haSyncStart command must be run successfully. Until this is done,
the system will remain out of synchronization.

Severity

WARNING

EM-1062

Message

<timestamp>, [EM-1062], <sequence-number>,, CRITICAL, <system-name>, Blade in

slot <Slot Id> faulted as it exceeds the maximum support limit of <Limit> blades

with Blade ID <Blade Type Id> in the chassis.

Probable Cause

Indicates too many blades of a particular type are in the system.

Recommended

Action

Remove the faulted blade.