Em-1060, Em-1061, Em-1062 – Dell POWEREDGE M1000E User Manual
Page 239
Fabric OS Message Reference
163
53-1001767-01
EM-1060
22
Recommended
Action
Replace the blade. Make sure the replacement is compatible with your switch type.
Severity
ERROR
EM-1060
Message
<timestamp>, [EM-1060], <sequence-number>,, WARNING, <system-name>, Stopping
synchronization of the system due to blade incompatibility with software version
on standby CP.
Probable Cause
Indicates a blade in the system is not supported by the release on the standby control processor
(CP).
Recommended
Action
Remove all blades of this type or upgrade your standby CP. Once an appropriate action is taken,
this CP must be rebooted or the haSyncStart command must be run successfully. Until this is done,
the system will remain out of synchronization.
Severity
WARNING
EM-1061
Message
<timestamp>, [EM-1061], <sequence-number>,, WARNING, <system-name>,
Synchronization halted. Remove all blades of type
<Blade Type Id>
or upgrade
your standby CP, then reboot or run haSyncStart.
Probable Cause
Indicates a blade in the system is not supported by the release on the standby control processor
(CP).
Recommended
Action
Remove all blades of this type or upgrade your standby CP. Once an appropriate action is taken,
this CP must be rebooted or the haSyncStart command must be run successfully. Until this is done,
the system will remain out of synchronization.
Severity
WARNING
EM-1062
Message
<timestamp>, [EM-1062], <sequence-number>,, CRITICAL, <system-name>, Blade in
slot <Slot Id> faulted as it exceeds the maximum support limit of <Limit> blades
with Blade ID <Blade Type Id> in the chassis.
Probable Cause
Indicates too many blades of a particular type are in the system.
Recommended
Action
Remove the faulted blade.
Severity