Fabric OS Message Reference

285

53-1001767-01

Chapter

41

FSSM System Messages

FSSM-1002

Message

<timestamp>, [FSSM-1002], <sequence-number>, SLOT cp-slot-number | CHASSIS, INFO,

<system-name>, HA State is in sync.

Probable Cause

Indicates that the high availability (HA) state for the active control processor (CP) is in
synchronization with the HA state of the standby CP. If the standby CP is healthy, then a failover is
nondisruptive. For more information on the haFailover command, refer to the Fabric OS Command
Reference Manual
.

Recommended

Action

No action is required.

Severity

INFO

FSSM-1003

Message

<timestamp>, [FSSM-1003], <sequence-number>, SLOT cp-slot-number | CHASSIS,

WARNING, <system-name>, HA State out of sync.

Probable Cause

Indicates that the high availability (HA) state for the active control processor (CP) is out of
synchronization with the HA state of the standby CP. If the active CP failover occurs when the HA
state is out of sync, the failover is disruptive.

Recommended

Action

If this message was logged as a result of a user-initiated action (such as running the Reboot
command), then no action is required.

Otherwise, issue the haSyncStart command on the active CP and try resynchronizing the HA state.
If the HA state does not become synchronized, run the haDump command to diagnose the
problem.

If the problem persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run
the supportSave command and contact your switch service provider.

Severity

WARNING

FSSM-1004

Message

<timestamp>, [FSSM-1004], <sequence-number>, SLOT cp-slot-number | CHASSIS, INFO,

<system-name>, Incompatible software version in HA synchronization.