Sulb-1025, Sulb-1026, Sulb-1030 – Dell POWEREDGE M1000E User Manual

Page 694: Sulb-1031

Advertising
background image

618

Fabric OS Message Reference

53-1001767-01

SULB-1025

97

SULB-1025

Message

<timestamp>, [SULB-1025], <sequence-number>,, WARNING, <system-name>, The blade

in slot <Slot number> will reboot with the new firmware.

Probable Cause

Indicates new firmware has been downloaded to the specified AP blade and that the AP blade will
reboot to activate it.

Recommended

Action

Wait for the blade to reboot.

Severity

WARNING

SULB-1026

Message

<timestamp>, [SULB-1026], <sequence-number>, AUDIT, WARNING, <system-name>,

Firmware commit operation started on the blade in slot <Slot number>.

Probable Cause

Indicates the firmwareCommit has started on the specified blade. The operation may be a normal
part of firmwareDownload, or it may have started to repair the secondary partition of the blade if
the secondary partition is corrupted.

Recommended

Action

No action is required.

Severity

WARNING

SULB-1030

Message

<timestamp>, [SULB-1030], AUDIT, WARNING, <system-name>, The switch has rebooted

during relocating the internal firmware image.

Probable Cause

Indicates there may be an error caused by an unexpected disruption of the firmwareDownload
command, for example, by powering the switch off and on in the middle of a firmwareDownload.
The error may also be caused by persistent storage hardware failure or by a software error.

Recommended

Action

The firmwareDownload command will continue after the switch has rebooted. Run the
firmwareDownloadStatus command to monitor progress. If the problem persists, contact your
switch service provider.

Severity

WARNING

SULB-1031

Message

<timestamp>, [SULB-1031], <sequence-number>, AUDIT, WARNING, <system-name>, The

switch is relocating an internal firmware image.

Probable Cause

Indicates the switch has rebooted with the new firmware and is relocating the AP firmware.

Advertising