Fabric OS Message Reference

623

53-1001767-01

Chapter

98

SWCH System Messages

SWCH-1001

Message

<timestamp>, [SWCH-1001], <sequence-number>,, ERROR, <system-name>, Switch is not

in ready state - Switch enable failed switch status= 0x<switch status>, c_flags =

0x<switch control flags>.

Probable Cause

Indicates the switch is enabled before it is ready.

Recommended

Action

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.

Severity

ERROR

SWCH-1002

Message

<timestamp>, [SWCH-1002], <sequence-number>,, INFO, <system-name>, Security

violation: Unauthorized device <wwn name of device> tries to flogin to port <port

number>.

Probable Cause

Indicates the device is not present in the authorized profile list.

Recommended

Action

Verify the device is authorized to log in to the switch. If the device is authorized, run the
secPolicyDump command to verify whether the specified device world wide name (WWN) is listed. If
it is not listed, run the secPolicyAdd command to add this device to an existing policy.

Severity

INFO

SWCH-1003

Message

<timestamp>, [SWCH-1003], <sequence-number>,, ERROR, <system-name>, Slot ENABLED

but Not Ready during recovery, disabling slot = <slot number>(<return value>).

Probable Cause

Indicates the slot state has been detected as inconsistent during failover or recovery.

Recommended

Action

On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn
command.

On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch.

Severity

ERROR