Ham system messages, Chapter 43, Ham-1001 – Dell POWEREDGE M1000E User Manual

Page 437: Ham-1002, Ham-1004, Chapter

Advertising
background image

Fabric OS Message Reference

361

53-1001767-01

Chapter

43

HAM System Messages

HAM-1001

Message

<timestamp>, [HAM-1001], <sequence-number>, SLOT cp-slpt-number | FFDC | CHASSIS,

FFDC, CRITICAL, <system-name>, Standby CP is not healthy, device <device name>

status BAD, Severity = <Log="YES" Class="NONE" Severity>

Probable Cause

Indicates that a standby control processor (CP) device error is reported by the high-availability
manager (HAM) Health Monitor, with a specific device and Log="YES” Class=”NONE" Severity level.
The severity level can be “critical”, “major”, or “minor”.

The active CP will continue to function normally, but because the standby CP is not healthy,
non-disruptive failover is not possible.

Recommended

Action

Reboot the standby CP blade by ejecting the card and reseating it. If the problem persists, replace
the standby CP. Run the supportSave command and contact your switch service provider.

Severity

CRITICAL

HAM-1002

Message

<timestamp>, [HAM-1002], <sequence-number>, SLOT cp-slot-number | CHASSIS, INFO,

<system-name>, Standby CP is healthy.

Probable Cause

Indicates that all of the standby control processor (CP) devices monitored by the high-availability
manager (HAM) Health Monitor report no error.

Recommended

Action

No action is required.

Severity

INFO

HAM-1004

Message

<timestamp>, [HAM-1004], <sequence-number>, SLOT cp-slot-number | CHASSIS, INFO,

<system-name>, Processor rebooted -

<Reboot Reason>.

Probable Cause

Indicates the system has been rebooted either because of a user action or an error. The switch
reboot can be initiated by the firmwareDownload, fastBoot, haFailover, and reboot commands.
Some examples of errors that might initiate this message are hardware errors, software errors,
compact flash errors, or memory errors. The reboot reasons can be any of the following:

Hafailover

Reset

Advertising