Ham system messages, Chapter 43, Ham-1001 – Dell POWEREDGE M1000E User Manual
Page 437: Ham-1002, Ham-1004, Chapter
Fabric OS Message Reference
361
53-1001767-01
Chapter
43
HAM System Messages
HAM-1001
Message
<timestamp>, [HAM-1001], <sequence-number>, SLOT cp-slpt-number | FFDC | CHASSIS,
FFDC, CRITICAL, <system-name>, Standby CP is not healthy, device <device name>
status BAD, Severity = <Log="YES" Class="NONE" Severity>
Probable Cause
Indicates that a standby control processor (CP) device error is reported by the high-availability
manager (HAM) Health Monitor, with a specific device and Log="YES” Class=”NONE" Severity level.
The severity level can be “critical”, “major”, or “minor”.
The active CP will continue to function normally, but because the standby CP is not healthy,
non-disruptive failover is not possible.
Recommended
Action
Reboot the standby CP blade by ejecting the card and reseating it. If the problem persists, replace
the standby CP. Run the supportSave command and contact your switch service provider.
Severity
CRITICAL
HAM-1002
Message
<timestamp>, [HAM-1002], <sequence-number>, SLOT cp-slot-number | CHASSIS, INFO,
<system-name>, Standby CP is healthy.
Probable Cause
Indicates that all of the standby control processor (CP) devices monitored by the high-availability
manager (HAM) Health Monitor report no error.
Recommended
Action
No action is required.
Severity
INFO
HAM-1004
Message
<timestamp>, [HAM-1004], <sequence-number>, SLOT cp-slot-number | CHASSIS, INFO,
<system-name>, Processor rebooted -
<Reboot Reason>.
Probable Cause
Indicates the system has been rebooted either because of a user action or an error. The switch
reboot can be initiated by the firmwareDownload, fastBoot, haFailover, and reboot commands.
Some examples of errors that might initiate this message are hardware errors, software errors,
compact flash errors, or memory errors. The reboot reasons can be any of the following:
•
Hafailover
•
Reset