Pdm-1008, Pdm-1009, Pdm-1010 – Dell POWEREDGE M1000E User Manual

Page 537

Advertising
background image

Fabric OS Message Reference

461

53-1001767-01

PDM-1008

75

Recommended

Action

Run the firmwareDownload command to reinstall the firmware.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.

Severity

WARNING

PDM-1008

Message

<timestamp>, [PDM-1008], <sequence-number>,, WARNING, <system-name>, Failed to

get the number of U_Ports.

Probable Cause

Indicates the parity data manager (PDM) system call to getCfg failed.

Recommended

Action

Run the firmwareDownload command to reinstall the firmware.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.

Severity

WARNING

PDM-1009

Message

<timestamp>, [PDM-1009], <sequence-number>,, WARNING, <system-name>, Can't update

Port Config Data.

Probable Cause

Indicates the parity data manager (PDM) system call to setCfg failed.

Recommended

Action

Run the firmwareDownload command to reinstall the firmware.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.

Severity

WARNING

PDM-1010

Message

<timestamp>, [PDM-1010], <sequence-number>,, WARNING, <system-name>, File open

failed: <file name>, errno= <errno>.

Probable Cause

Indicates the parity data manager (PDM) process could not open the specified file.

Recommended

Action

Run the firmwareDownload command to reinstall the firmware.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.

Severity

WARNING

Advertising