Hil-1502, Hil-1503, Hil-1504 – Dell POWEREDGE M1000E User Manual

Page 454

Advertising
background image

378

Fabric OS Message Reference

53-1001767-01

HIL-1502

45

Recommended

Action

Run the fanShow command to verify all the fans are working properly.

Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.

Severity

WARNING

HIL-1502

Message

<timestamp>, [HIL-1502], <sequence-number>, FFDC, CRITICAL, <system-name>, Slot

<slot number>, high temperature (<measured temperature>). Unit will be shut down

in 2 minutes if temperature remains high.

Probable Cause

Indicates that the temperature of this blade has risen above the critical threshold. This usually
follows a high-temperature message.

Recommended

Action

Run the fanShow command to verify all the fans are working properly.

Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.

If the message persists, replace the blade.

Severity

CRITICAL

HIL-1503

Message

<timestamp>, [HIL-1503], <sequence-number>, FFDC, CRITICAL, <system-name>, Slot

<

slot number

>

, unit shutting down.

Probable Cause

Indicates that the temperature of this blade has been above the maximum threshold for at least
two minutes. The blade is shut down to prevent damage. This usually follows a high-temperature
warning message.

Recommended

Action

Run the fanShow command to verify all the fans are working properly.

Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.

If the message persists, replace the faulty blade.

Severity

CRITICAL

HIL-1504

Message

<timestamp>, [HIL-1504], <sequence-number>,, INFO, <system-name>, System within

normal temperature specifications (<measured temperature> C).

Probable Cause

Indicates that temperatures in the system have returned to normal.