Ag-1019, Ag-1020, Ag-1021 – Dell POWEREDGE M1000E User Manual

Page 106

Advertising
background image

30

Fabric OS Message Reference

53-1001767-01

AG-1019

2

Recommended

Action

Run the switchShow command to display the status of all ports in the system. Run the portCfgShow
command to display a list of ports currently configured as N_Ports. Ensure that the host is
connected to an F_port.

Severity

ERROR

AG-1019

Message

<timestamp>, [AG-1019], <sequence-number>,, WARNING, <system-name>, Unable to

failover N_Port <port>. No other N Port in port group:<pgid> is online.

Probable Cause

Indicates that failover across port groups is not supported.

Recommended

Action

Check whether or not an alternate N_Port is configured in this port group.

Severity

WARNING

AG-1020

Message

<timestamp>, [AG-1020], <sequence-number>,, INFO, <system-name>, F_Ports to

N_Ports route/mapping has been changed.

Probable Cause

Indicates that F_Port -to-N_Port mapping has been changed because the switch has come online
or some new N_Port/F_Port has come online.

Recommended

Action

Run the ag --mapshow command to display the updated F_Port-to-N_Port mapping.

Severity

INFO

AG-1021

Message

<timestamp>, [AG-1021], <sequence-number>,, WARNING, <system-name>, Unable to do

Preferred-Failover of F_Port <port>. Failover across different fabric is not

supported.

Probable Cause

Indicates that the failover does not get blocked between two fabrics, although it is not a supported
configuration.

Recommended

Action

Change the preferred N_Port settings for this F_Port using the ag --prefset command.

Choose the preferred N_Port such that it is in the same fabric as the primary N_Port of this F_Port.
Use the ag --show command to check the fabric connectivity of N_Ports.

Severity

WARNING

Advertising