RAS-1001
Message
<timestamp>, [RAS-1001], <sequence-number>,, INFO, <system-name>, First failure
data capture (FFDC) event occurred.
Probable Cause
Indicates that a failure data event was captured.
Recommended
Action
Run the supportFtp command (as needed) to set up automatic FTP transfers and run the
supportSave command then contact your switch service provider.
Severity
INFO
RAS-1002
Message
<timestamp>, [RAS-1002], <sequence-number>,, WARNING, <system-name>, First
failure data capture (FFDC) maximum storage size (
<log size limit>
MB) was
reached.
Probable Cause
Indicates that the maximum storage size for FFDC data capture is reached.
Recommended
Action
Run the supportSave command and contact your switch service provider.
Severity
WARNING
RAS-1004
Message
<timestamp>, [RAS-1004], <sequence-number>, FFDC, WARNING, <system-name>,
Software 'verify' error detected.
Probable Cause
Indicates an internal software error.
Recommended
Action
Run the supportSave command and contact your switch service provider.
Severity
WARNING
RAS-1005
Message
<timestamp>, [RAS-1005], <sequence-number>, FFDC, WARNING, <system-name>,
Software 'assert' error detected.