RAS System Messages

RAS-1001

Message

<timestamp>, [RAS-1001], <sequence-number>,, INFO, <system-name>, First failure

data capture (FFDC) event occurred.

Probable Cause

Indicates that a failure data event was captured.

Recommended

Action

Run the supportFtp command (as needed) to set up automatic FTP transfers and run the
supportSave command then contact your switch service provider.

Severity

INFO

RAS-1002

Message

<timestamp>, [RAS-1002], <sequence-number>,, WARNING, <system-name>, First

failure data capture (FFDC) maximum storage size (

<log size limit>

MB) was

reached.

Probable Cause

Indicates that the maximum storage size for FFDC data capture is reached.

Recommended

Action

Run the supportSave command and contact your switch service provider.

Severity

WARNING

RAS-1004

Message

<timestamp>, [RAS-1004], <sequence-number>, FFDC, WARNING, <system-name>,

Software 'verify' error detected.

Probable Cause

Indicates an internal software error.

Recommended

Action

Run the supportSave command and contact your switch service provider.

Severity

WARNING

RAS-1005

Message

<timestamp>, [RAS-1005], <sequence-number>, FFDC, WARNING, <system-name>,

Software 'assert' error detected.

Advertising