Fw-1244, Fw-1245, Fw-1246 – Dell POWEREDGE M1000E User Manual

Page 395

Advertising
background image

Fabric OS Message Reference

319

53-1001767-01

FW-1244

42

Severity

INFO

FW-1244

Message

<timestamp>, [FW-1244], <sequence-number>,, INFO, <system-name>, <Label>, value

has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.

Probable Cause

Indicates that the number of end-to-end (EE) word frames that the switch receives has changed.
Receive performance messages appear due to the number of word frames that travel from the
configured S_ID to the D_ID pair.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

FW-1245

Message

<timestamp>, [FW-1245], <sequence-number>,, INFO, <system-name>, <Label>, is

below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>

<Unit>.

Probable Cause

Indicates that the number of end-to-end (EE) word frames that the switch receives has fallen below
the low boundary. Receive performance messages appear due to the number of word frames that
travel from the configured S_ID to the D_ID pair.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

FW-1246

Message

<timestamp>, [FW-1246], <sequence-number>,, INFO, <system-name>, <Label>, is

above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>

<Unit>.

Probable Cause

Indicates that the number of end-to-end (EE) word frames that the switch receives has risen above
the high boundary. Receive performance messages appear due to the number of word frames that
travel from the configured S_ID to the D_ID pair.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

Advertising