Trce system messages, Chapter 102 trce system messages, Trce-1001 – Dell POWEREDGE M1000E User Manual

Page 711: Trce-1002, Trce-1003, Chapter

Advertising
background image

Fabric OS Message Reference

635

53-1001767-01

Chapter

102

TRCE System Messages

TRCE-1001

Message

<timestamp>, [TRCE-1001], <sequence-number>,, WARNING, <system-name>, Trace dump

available< optional slot indicating on which slot the dump occurs >! (reason:

<Text explanation of what triggered the dump. (PANIC DUMP, WATCHDOG EXPIRED,

MANUAL, TRIGGER)>)

Probable Cause

Indicates that trace dump files have been generated on the switch or the indicated slot. The reason
field indicates the cause for generating the dump as one of the following:

PANICDUMP generated by panic dump

WATCHDOG EXPIRED generated by hardware watchdog expiration

MANUAL generated by the tracedump -n command

TRIGGER when triggered by a specific Message ID generated by CRITICAL RASLog message or
RASLog message trigger setup using the traceTrig command.

Recommended

Action

Run the supportFtp command to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.

Severity

WARNING

TRCE-1002

Message

<timestamp>, [TRCE-1002], <sequence-number>,, INFO, <system-name>, Trace dump<

optional slot indicating on which slot the dump occurs > automatically transferred

to FTP address ' <FTP target designated by user> '.

Probable Cause

Indicates that a trace dump has occurred on the switch or the indicated slot and it is successfully
transferred from the switch automatically.

Recommended

Action

No action is required.

Severity

INFO

TRCE-1003

Message

<timestamp>, [TRCE-1003], <sequence-number>,, ERROR, <system-name>, Trace dump<

optional slot indicating on which slot the dump occurs > was not transferred due

to FTP error.

Advertising