Trce system messages, Chapter 102 trce system messages, Trce-1001 – Dell POWEREDGE M1000E User Manual
Page 711: Trce-1002, Trce-1003, Chapter
Fabric OS Message Reference
635
53-1001767-01
Chapter
102
TRCE System Messages
TRCE-1001
Message
<timestamp>, [TRCE-1001], <sequence-number>,, WARNING, <system-name>, Trace dump
available< optional slot indicating on which slot the dump occurs >! (reason:
<Text explanation of what triggered the dump. (PANIC DUMP, WATCHDOG EXPIRED,
MANUAL, TRIGGER)>)
Probable Cause
Indicates that trace dump files have been generated on the switch or the indicated slot. The reason
field indicates the cause for generating the dump as one of the following:
•
PANICDUMP generated by panic dump
•
WATCHDOG EXPIRED generated by hardware watchdog expiration
•
MANUAL generated by the tracedump -n command
•
TRIGGER when triggered by a specific Message ID generated by CRITICAL RASLog message or
RASLog message trigger setup using the traceTrig command.
Recommended
Action
Run the supportFtp command to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity
WARNING
TRCE-1002
Message
<timestamp>, [TRCE-1002], <sequence-number>,, INFO, <system-name>, Trace dump<
optional slot indicating on which slot the dump occurs > automatically transferred
to FTP address ' <FTP target designated by user> '.
Probable Cause
Indicates that a trace dump has occurred on the switch or the indicated slot and it is successfully
transferred from the switch automatically.
Recommended
Action
No action is required.
Severity
INFO
TRCE-1003
Message
<timestamp>, [TRCE-1003], <sequence-number>,, ERROR, <system-name>, Trace dump<
optional slot indicating on which slot the dump occurs > was not transferred due
to FTP error.