Fcoe-1030, Fcoe-1031, Fcoe-1032 – Dell POWEREDGE M1000E User Manual

Page 284: Fcoe-1033

Advertising
background image

208

Fabric OS Message Reference

53-1001767-01

FCOE-1030

31

Probable Cause

Indicates a version mismatch between the FLOGI and the FDISCs.

Recommended

Action

No action is required.

Severity

WARNING

FCOE-1030

Message

<timestamp>, [FCOE-1030], <sequence-number>,, WARNING, <system-name>, Version

mismatch between FIP LOGO and root VN port.

Probable Cause

Indicates a version mismatch between the FIP logout and base FLOGI.

Recommended

Action

No action is required.

Severity

WARNING

FCOE-1031

Message

<timestamp>, [FCOE-1031], <sequence-number>,, WARNING, <system-name>, FCoE port

deleted port <prt> slot <slt>.

Probable Cause

Indicates a FCoE port has been deleted.

Recommended

Action

No action is required.

Severity

WARNING

FCOE-1032

Message

<timestamp>, [FCOE-1032], <sequence-number>,, WARNING, <system-name>, We are in

WARM RECOVERING state.

Probable Cause

Indicates a HA failover or reboot may be in progress.

Recommended

Action

No action is required.

Severity

WARNING

FCOE-1033

Message

<timestamp>, [FCOE-1033], <sequence-number>,, WARNING, <system-name>, FIP v1

FLOGI received - VF port in use.

Probable Cause

Indicates a device is trying to login to a port that already has something logged in.