53-1001767-01

PDM-1004

75

PDM-1004

Message

<timestamp>, [PDM-1004], <sequence-number>,, WARNING, <system-name>, PDM memory

shortage.

Probable Cause

Indicates the parity data manager (PDM) process ran out of memory.

Recommended

Action

Reboot or power cycle the switch.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.

Severity

WARNING

PDM-1005

Message

<timestamp>, [PDM-1005], <sequence-number>,, WARNING, <system-name>, FSS register

failed.

Probable Cause

Indicates the parity data manager (PDM) failed to register with the Fabos synchronization service
(FSS).

Recommended

Action

Run the firmwareDownload command to reinstall the firmware.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.

Severity

WARNING

PDM-1006

Message

<timestamp>, [PDM-1006], <sequence-number>,, WARNING, <system-name>, Too many

files in sync.conf.

Probable Cause

Indicates the configuration file sync.conf contains too many entries.

Recommended

Action

Run the firmwareDownload command to reinstall the firmware.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.

Severity

WARNING

PDM-1007

Message

<timestamp>, [PDM-1007], <sequence-number>,, WARNING, <system-name>, File not

created:

<file name> errno= <errno>.

Probable Cause

Indicates the parity data manager (PDM) process failed to create the specified file.

Advertising