HIL-1206

45

HIL-1206

Message

<timestamp>, [HIL-1206], <sequence-number>,, ERROR, <system-name>, Fan <fan

number> sensor <sensor number> , speed (<measured speed> RPM) below threshold.

Probable Cause

Indicates that the specified fan speed (in RPMs) has fallen below the minimum threshold. This
problem can quickly cause the switch to overheat. This message is specific to nonbladed switches
and is not applicable to the Brocade 24000 or 48000.

Recommended

Action

For the Brocade 4100, 4900, 7500, and AP7600, replace the fan field-replaceable unit (FRU).

Severity

ERROR

HIL-1207

Message

<timestamp>, [HIL-1207], <sequence-number>,, ERROR, <system-name>, Fan

<fan

number>

is faulty.

Probable Cause

Indicates that the fan is faulty.

Recommended

Action

Use the tempShow command to verify that the switch temperatures are within operational ranges.
Refer to the hardware reference manual for the temperature range of your switch.

Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.

Use the fanShow command to monitor the status of the fan generating this error.

If the fan continues to generate this message, replace the switch because the fan is not
field-replaceable.

Severity

ERROR

HIL-1208

Message

<timestamp>, [HIL-1208], <sequence-number>,, INFO, <system-name>, Fan

<fan

number>

is not faulty.

Probable Cause

Indicates that the fan is not faulty.

Recommended

Action

This can only occur on switches with non-removable fans. It follows a previous indication of
faultiness.

If the fan continues to generate this message, it indicates oscillation between faulty and non-faulty
behavior. Replace the switch because the fan is not field-replaceable.

Severity

INFO