Fabric OS Message Reference

95

53-1001767-01

Chapter

15

CHASSIS System Messages

CHASSIS-1002

Message

<timestamp>, [CHASSIS-1002], <sequence-number>,, ERROR, <system-name>,

ki_gd_register_action failed with rc =<ret val>.

Probable Cause

Indicates an internal error.

Recommended

Action

For a bladed system, execute the slotPowerOff command and slotPowerOn commands on the
blade to recover the system. For a non-bladed system, execute the fastBoot command on the
switch to recover the system.

Severity

ERROR

CHASSIS-1003

Message

<timestamp>, [CHASSIS-1003], <sequence-number>,, ERROR, <system-name>, Slot

ENABLED but Not Ready during recovery, disabling slot = <slot number> rval =

<return value>.

Probable Cause

Indicates that the slot state has been detected as inconsistent during failover or recovery.

Recommended

Action

On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn
command. On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch.

Severity

ERROR

CHASSIS-1004

Message

<timestamp>, [CHASSIS-1004], <sequence-number>,, ERROR, <system-name>, Blade

attach failed during recovery, disabling slot = <slot number>, rval = <return

value>.

Probable Cause

Indicates that a blade has failed during failover or recovery.

Recommended

Action

On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn
command. On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900,
5000, 7500, or AP7600 switch, reboot or power cycle the switch.

Severity

ERROR