Fabric OS Message Reference

303

53-1001767-01

FW-1136

42

FW-1136

Message

<timestamp>, [FW-1136], <sequence-number>,, INFO, <system-name>, <Label>, is

between high and low boundaries(High=<High value>, Low=<Low value>). Current value

is <Value> <Unit>.

Probable Cause

Indicates that the number of fabric logins has changed from a value outside of the acceptable
range to a value within the acceptable range. Fabric logins occur when a port or device initializes
with the fabric. The event is called a fabric login or FLOGI.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

FW-1137

Message

<timestamp>, [FW-1137], <sequence-number>,, INFO, <system-name>, <Label>, value

has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.

Probable Cause

Indicates that the number of small form-factor pluggable (SFP) state changes has changed. SFP
state changes occur when the SFP is inserted or removed.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

FW-1138

Message

<timestamp>, [FW-1138], <sequence-number>,, INFO, <system-name>, <Label>, is

below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>

<Unit>.

Probable Cause

Indicates that the number of small form-factor pluggable (SFP) state changes has fallen below the
low boundary. SFP state changes occur when the SFP is inserted or removed. A low number of SFP
state changes means that the switch is functioning normally.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

FW-1139

Message

<timestamp>, [FW-1139], <sequence-number>,, INFO, <system-name>, <Label>, is

above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>

<Unit>.