630

Fabric OS Message Reference

53-1001767-01

SYSC-1004

99

It could also indicate that the current option number could not be read from the chassis option
storage device (the world wide name (WWN) card).

This message occurs only on the Brocade 24000 and 48000.

Recommended

Action

As indicated in the message, run the chassisConfig command to change to one that is valid on this
platform running this firmware. Note that the chassisConfig option 1 should be valid for all
platforms running any valid firmware.

Severity

CRITICAL

SYSC-1004

Message

<timestamp>, [SYSC-1004], <sequence-number>,, INFO, <system-name>, Daemon

<Daemon name to restart>

restart successful

Probable Cause

Indicates that a terminated daemon is being restarted by the system automatically.

Recommended

Action

Use the supportSave command to gather troubleshooting data.

Severity

INFO

SYSC-1005

Message

<timestamp>, [SYSC-1005], <sequence-number>,, WARNING, <system-name>, Daemon

<Daemon name to restart> is not restarted (Reason: <Restart failure reason>)

Probable Cause

Indicates a terminated daemon has not restarted, either a restart limit has been reached or a
restart action has failed.

Recommended

Action

Use the supportSave command to gather troubleshooting data. Issue a reboot or haFailover
command to recover the system and limit the traffic disruption.

Severity

WARNING