17 snmp-server host, 17 snmp-server host -100 – PLANET WGSW-52040 User Manual

Page 101

Advertising
background image

1-100

1.4.17 snmp-server host

Command:

snmp-server host { <host-ipv4-address> | <host-ipv6-address> } {v1 | v2c | {v3 {NoauthNopriv | AuthNopriv |

AuthPriv}}} <user-string>

no snmp-server host { <host-ipv4-address> | <host-ipv6-address> } {v1 | v2c | {v3 {NoauthNopriv |

AuthNopriv | AuthPriv}}} <user-string>

Function:

As for the v1/v2c versions this command configures the IPv4 or IPv6 address and Trap community character string of

the network manage station receiving the SNMP Trap message. And for v3 version, this command is used for

receiving the network manage station IPv4 or IPv6 address and the Trap user name and safety level; the “no” form of

this command cancels this IPv4 or IPv6 address.

Command Mode:

Global Mode.

Parameter:

<host-ipv4-addr> is IP address of NMS management station which receives Trap message.

<host-ipv6-addr> is IPv6 address of NMS management station which receives Trap message.

v1 | v2c | v3 is the version number when sending the trap.

NoauthNopriv | AuthNopriv | AuthPriv is the safety level v3 trap is applied, which may be non encrypted and non

authentication, non encrypted and authentication, encrypted and authentication.

<user-string> is the community character string applied when sending the Trap message at v1/v2, and will be the

user name at v3.

Usage Guide:

The Community character string configured in this command is the default community string of the RMON event

group. If the RMON event group has no community character string configured, the community character string

configured in this command will be applied when sending the Trap of RMON, and if the community character string is

configured, its configuration will be applied when sending the RMON trap. This command allows to configure IPv4 or

IPv6 addresses of SNMP management station that receive Trap message at the same time, but IPv4 and IPv6

addresses of v1 and v2c version are less than 8 in all.

Example:

Configure an IP address to receive Trap

Switch(config)#snmp-server host 1.1.1.5 v1 usertrap

Delete an IPv6 address to receive Trap.

Switch(config)#no snmp-server host 2001::1 v1 usertrap

Advertising