4 mac-address-table notification interval, 4 mac-address-table notification interval -89 – PLANET WGSW-52040 User Manual
Page 320

18-89
Function:
Configure the maximum history-size for storing MAC changing message, the no command restores the default
value.
Parameter:
history-size: data length of sending the notification, its range from 1 to 500.
Default:
10.
Command Mode:
Global mode
Usage Guide:
After the global switch is disabled, this command is also able to be configured sequentially.
Example:
Change the maximum history-size to be 256.
Switch(Config)#mac-address-table notification history-size 256
18.3.4 mac-address-table notification interval
Command:
mac-address-table notification interval <0-86400>
no mac-address-table notification interval
Function:
Configure the interval for sending the MAC address notification, the no command restores the default interval.
Parameter:
interval: interval for sending the notification, unit is second, its range from 0 to 86400.
Default:
30s.
Command Mode:
Global mode