Ethernet, Oam errored, Frame – PLANET WGSW-52040 User Manual

Page 208: Seconds threshold high

Advertising
background image

11-207

Function:

Configure the detection period of errored frame period event, no command restores the default value.

Parameters:

<seconds> is the time for counting the specified frame number, its range from 1 to 300, unit is 200ms.

Command Mode:

Port mode

Default:

5.

Usage Guide:

Detect errored frame of the port after the time of specific detection period. If the number of errored frame is larger

than or equal to the threshold, corresponding event is induced and the device notifies the peer through OAMPDU.

When sending the packets, the maximum number of frames is filled as the value of window in errored frame period

event. The conversion rule is maximum number of frames= interface bandwidth×detection period of errored frame

period event(s)ч(64Ч8), of which the detection period is the number of seconds in window of the configuration.

Example:

Configure the detection period of errored frame period event on port 1/4 to be 10s.

Switch(Config-If-Ethernet1/4)#ethernet-oam errored-frame-period window 50

11.13 ethernet-oam errored-frame-seconds threshold high

Command:

ethernet-oam errored-frame-seconds threshold high {<high-seconds> | none}

no ethernet-oam errored-frame-seconds threshold high

Function:

Configure the high threshold of errored frame seconds event, no command restores the default value.

Parameters:

<high-seconds>, the high detection threshold of errored frame seconds event, ranging from 2 to 65535 seconds.

none, cancel the high threshold configuration.

Command Mode:

Port mode

Advertising