Chapter 52 Commands for MRPP

52.1 control-vlan

Command:

control-vlan <vid>

no control-vlan

Function:

Configure control VLAN ID of MRPP ring; the “no control-vlan” command deletes control VLAN ID.

Parameter:

<vid> expresses control VLAN ID, the valid range is from 1 to 4094.

Command Mode:

MRPP ring mode

Default:

None

Usage Guide:

The command specifies Virtual VLAN ID of MRPP ring, currently it can be any value in 1-4094. To avoid confusion, it

is recommended that the ID is non-configured VLAN ID, and the same to MRPP ring ID. In configuration of MRPP

ring of the same MRPP loop switches, the control VLAN ID must be the same, otherwise the whole MRPP loop may

not be able to work normally or form broadcast.

The mrpp enable command must be start before the control-vlan command be used. If primary port, secondary port,

node-mode and enable commands all be configured after control-vlan, the mrpp-ring function is enabled.

Example:

Configure control VLAN of mrpp ring 4000 is 4000.

Switch(config)#mrpp ring 4000

Switch(mrpp-ring-4000)#control-vlan 4000

52.2 clear mrpp statistics

Command:

clear mrpp statistics [<ring-id>]