8 lldp neighbors max-num, 9 lldp notification interval, Lldp neighbors max – PLANET WGSW-52040 User Manual
Page 181: Lldp notification interval

8-180
Example:
Set the value of the aging time multiplier as 6.
Switch(config)#lldp msgTxHold 6
8.8 lldp neighbors max-num
Command:
lldp neighbors max-num <value>
no lldp neighbors max-num
Function:
Set the maximum number of entries can be stored in Remote MIB.
Parameters:
<value> is the configured number of entries, ranging from 5 to 500.
Default:
The maximum number of entries can be stored in Remote MIB is 100.
Command Mode:
Port Configuration Mode.
Usage Guide:
The maximum number of entries can be stored in Remote MIB.
Example:
Set the Remote as 200 on port ethernet 1/5 of the switch.
Switch(config)#in ethernet 1/5
Switch(Config-If-Ethernet1/5)# lldp neighbors max-num 200
8.9 lldp notification interval
Command:
lldp notification interval <seconds>
no lldp notification interval
Function: