12 dot1x max-req, X max – PLANET WGSW-52040 User Manual

Page 635

Advertising
background image

39-175

Usage Guide:

When users who passed the certification according to mac changed among different ports, delete the user for the

new certification. The command should be enable to delete the user.

Example:

When the dot1x certification according to mac is down, delete the user who passed the certification of the port

.

Switch(config)#dot1x macbased port-down-flush

39.12 dot1x max-req

Command:

dot1x max-req <count>

no dot1x max-req

Function:

Sets the number of EAP request/MD5 frame to be sent before the switch re-initials authentication on no supplicant

response; the “no dot1x max-req” command restores the default setting.

Parameters:

<count> is the times to re-transfer EAP request/ MD5 frames, the valid range is 1 to 10.

Command mode:

Global Mode.

Default:

The default maximum for retransmission is 2.

Usage Guide:

The default value is recommended in setting the EAP request/ MD5 retransmission times.

Example:

Changing the maximum retransmission times for EAP request/ MD5 frames to 5 times.

Switch(config)#dot1x max-req 5

Advertising