PLANET WGSW-52040 User Manual

Page 220

Advertising
background image

11-219

Max_OAMPDU_Size=1518

--------------------------------------------------------------------------

OAM Remote Flags Field:

Link Fault=0 Dying Gasp=0 Critical Event=0

Field

Description

Remote_Mac_Address

MAC address of remote OAM entity

local _mode

Working mode of Ethernet OAM:

active, the port is set as active mode;

passive, the port is set as passive mode.

local_pdu

The way in which the local end processes Ethernet OAMPDUs:

RX_INFO, the port only receives Information OAMPDUs and does not

send any Ethernet OAMPDUs.

LF_INFO, the port only sends Information OAMPDU packets without

Information TLV and with their link error flag bits being set.

INFO, the port only sends and receives Information OAMPDU packets.

ANY, the port sends and receives any OAMPDU packets.

local_mux_action

Working mode of the local transmitter:

FWD, the port can send any packets;

DISCARD, the port only sends OAMPDU packets and discards others.

local_par_action

Working mode of the local receiver in the following:

FWD, receiving any packets is allowed;

DISCARD, only OAMPDU packets is received while others are

discarded;

LB, OAM remote loopback is enabled on the port. In this case, all the

packets except OAMPDU packets received are returned to their

sources along the ways they come.

Loopback Supported

Whether support remote loopback: YES for support and NO for not.

Unidirectional Support

Whether support unidirectional transmission: YES for support and NO

for not.

Link Events

Whether support general link events: YES for support and NO for not.

Remote Failure

Whether support severe link events: YES for support and NO for not.

Max_OAMPDU_Size

The maximum length of OAMPDU is supported.

Link Fault

Whether occur a Link Fault event: 0 for no and 1 for yes.

Dying Gasp

Whether occur a Dying Gasp event: 0 for no and 1 for yes.

Critical Event

Whether occur a Critical Event: 0 for no and 1 for yes.

Advertising