3 sflow counter-interval, Sflow counter, Interval – PLANET WGSW-52040 User Manual
Page 804

56-344
Parameter:
sflowtrend is the analyzer of Inmon.
Command Mode:
Global Mode
Default:
Do not configure
Usage Guide:
Configure this command when using sFlowTrend.
Example:
Switch(config)#sflow analyzer sflowtrend
56.3 sflow counter-interval
Command:
sflow counter-interval <interval-value>
no sflow counter-interval
Function:
Configure the max interval of the sFlow statistic sampling; the “no” form of this command deletes the statistic
sampling interval value.
Parameter:
<interval-value> is the value of the interval with a valid range of 20~120 and shown in second.
Command Mode:
Port Mode
Default:
No default value
Usage Guide:
If no statistic sampling interval is configured, there will not be any statistic sampling on the interface.