3 sflow counter-interval, Sflow counter, Interval – PLANET WGSW-52040 User Manual

Page 804

Advertising
background image

56-344

Parameter:

sflowtrend is the analyzer of Inmon.

Command Mode:

Global Mode

Default:

Do not configure

Usage Guide:

Configure this command when using sFlowTrend.

Example:

Switch(config)#sflow analyzer sflowtrend

56.3 sflow counter-interval

Command:

sflow counter-interval <interval-value>

no sflow counter-interval

Function:

Configure the max interval of the sFlow statistic sampling; the “no” form of this command deletes the statistic

sampling interval value.

Parameter:

<interval-value> is the value of the interval with a valid range of 20~120 and shown in second.

Command Mode:

Port Mode

Default:

No default value

Usage Guide:

If no statistic sampling interval is configured, there will not be any statistic sampling on the interface.

Advertising