15 ethernet-oam errored-frame-seconds window, Ethernet, Oam errored – PLANET WGSW-52040 User Manual

Page 210: Frame, Seconds window, Symbol, Period threshold high

Advertising
background image

11-209

Example:

Configure the low threshold of errored frame seconds event on port 1/4 to be 100.

Switch(Config-If-Ethernet1/4)#ethernet-oam errored-frame-seconds threshold low 100

11.15 ethernet-oam errored-frame-seconds window

Command:

ethernet-oam errored-frame-seconds window <seconds>

no ethernet-oam errored-frame-seconds window

Function:

Configure the detection period of errored frame seconds event, no command restores the default value.

Parameters:

<seconds> is the time for counting the specified frame number, its range from 50 to 450, unit is 200ms.

Command Mode:

Port mode

Default:

300.

Usage Guide:

Detect errored frame seconds of the port after the time of specific detection period. If the number of errored frame

seconds is larger than or equal to the threshold, corresponding event is induced and the device notified the peer

through OAMPDU.

Example:

Configure the detection period of errored frame seconds event on port 1/4 to be 120s.

Switch(Config-If-Ethernet1/4)#ethernet-oam errored-frame-seconds window 600

11.16 ethernet-oam errored-symbol-period threshold high

Command:

ethernet-oam errored-symbol-period threshold high {<high-symbols> | none}

no ethernet-oam errored-symbol-period threshold high

Function:

Advertising