Example:

Set the statistic sampling interval on the interface e1/1 to 20 seconds.

Switch(Config-If-Ethernet1/1)#sflow counter-interval 20

56.4 sflow data-len

Command:

sflow data-len <length-value>

no sflow data-len

Function:

Configure the max length of the sFlow packet data; the “no sflow data-len” command restores the default value.

Parameter:

<length-value> is the value of the length with a value range of 500-1470.

Command Mode:

Port Mode.

Default:

The value is 1400 by default.

Usage Guide:

When combining several samples to a sFlow group to be sent, the length of the group excluding the MAC head and

IP head parts should not exceed the configured value.

Example:

Configure the max length of the sFlow packet data to 1000.

switch (Config-If-Ethernet1/2)#sflow data-len 1000

56.5 sflow destination