PLANET WGSW-52040 User Manual

Page 218

Advertising
background image

11-217

Loopback Supported=YES

Unidirectional Support=YES

Link Events=YES

Remote Failure=YES

local_pdu=INFO

local_mux_action=FWD

local_par_action=DISCARD

Max_OAMPDU_Size=1518

------------------------------------------------------------------------

OAM_local_flags_field:

Link Fault=0 Dying Gasp=0 Critical Events=0

------------------------------------------------------------------------

Packet statistic:

Packets Send Receive

OAMPDU 553 21

Information 552 21

Event Notification 1 0

Loopback Control 0 0

------------------------------------------------------------------------

Field

Description

oam_status

Status of Ethernet OAM:

enable, OAM is enabled;

disable, OAM is not enabled.

local _mode

Working mode of Ethernet OAM:

active, the port is set as active mode;

passive, the port is set as passive mode.

Period

Transmission period of packets

Timeout

Timeout of connection

local_pdu

The way in which the local end processes Ethernet OAMPDUs:

RX_INFO, the port only receives Information OAMPDUs and does not

send any Ethernet OAMPDUs.

LF_INFO, the port only sends Information OAMPDU packets without

Information TLV and with their link error flag bits being set.

INFO, the port only sends and receives Information OAMPDU packets.

ANY, the port sends and receives any OAMPDU packets.

local_mux_action

Working mode of the local transmitter:

FWD, the port can send any packets;

DISCARD, the port only sends OAMPDU packets and discards others.

Advertising