Input v-ref 1cn-5, Input sg 1cn-6 – Yaskawa SGDB User Manual

Page 103

Advertising
background image

3.2 Setting Parameters According to Host Controller

91

Examples:

+3 V input → Rated torque in forward direction
+9 V input → 300% of rated torque in forward direction
−0.3 V input → 10% of rated torque in reverse direction

Parameter Cn-13 can be used to change the voltage input range.

Example of Input Circuit:
See the figure on the right.

• For noise control, always use twisted-

pair cables.

• Example of Variable Resistor for Speed Setting:

Type 25HP-10B manufactured by Sakae Tsushin Kogyo Co., Ltd.

Input V-REF

1CN-5

Speed Reference Input (or

Speed Limit Input)

For Speed/Torque

Control Only

Input SG

1CN-6

Signal Ground for Speed

Reference Input

For Speed/Torque

Control Only

These signals are used when speed control is se-
lected.

For normal speed control, always connect these
signal terminals.

Motor speed is controlled so that it is proportional
to the input voltage between V-REF and SG.

Standard Example
Cn-03 = 500: This setting means that 6 V is equivalent to 3000 min

−1

.

Examples:

+6 V input → 3000 min

−1

in forward direction

+1 V input → 500 min

−1

in forward direction

−3 V input → 1500 min

−1

in reverse direction

Parameter Cn-03 can be used to change the voltage input range. (This is also applicable
to speed restriction.)

Example of Input Circuit:
See the figure on the right.

• For noise control, always use twisted-

pair cables.

• Example of Variable Resistor for Speed Setting:

Type 25HP-10B manufactured by Sakae Tsushin Kogyo Co., Ltd.

3

1/2 W or more

SGDB

SERVOPACK

1CN-9

1CN-10

Reference

speed (min

−1

)

Standard

setting

Input voltage

(V)

Set the slope

in Cn-03

(VREFGN).

−1500

−3000

−4500

1/2 W or more

SGDB

SERVOPACK

1CN-5

1CN-6

Advertising